Question and answer
Which type of circuit is becoming more common in residential electrical design and construction? A. Hazardous-area circuit B. Three-phase circuit C. 480-volt circuit D. Communication circuit
Communication circuit is becoming more common in residential electrical design and construction.
Question|Asked by amelvin41
Asked 2/2/2019 1:25:32 PM
Updated 4/20/2021 11:04:24 PM
1 Answer/Comment
f
Get an answer
New answers
Rating
3
Communication circuit is becoming more common in residential electrical design and construction.
Added 4/20/2021 11:04:24 PM
This answer has been confirmed as correct and helpful.
Comments

There are no comments.

Add an answer or comment
Log in or sign up first.
Questions asked by amelvin41
A box that has self-contained cable clamps holds two light switches. A two-wire No. 12 cable with ground feeds the box, and a pair of two-wire No. 12 cables (four conductors) with ground wires leaves the box to feed the light fixtures. The second switch is fed by a No. 12 jumper wire from the first switch. Which one of the following box combinations would furnish the minimum allowable volume? A. Two 3-inch 2-inch 21 2-inch gangable device boxes B. Two 3-inch 2-inch 11 2-inch ...
Question|Asked by amelvin41
Not Answered
Updated 9/14/2022 6:35:33 PM
1 Answer/Comment
A box that has self-contained cable clamps holds two light switches. A two-wire No. 12 cable with ground feeds the box, and a pair of two-wire No. 12 cables (four conductors) with ground wires leaves the box to feed the light fixtures. The second switch is fed by a No. 12 jumper wire from the first switch. The following box combinations would furnish the minimum allowable volume: Two 3-inch
2-inch 2 1/4-inch gangable device boxes.

Added 9/14/2022 6:35:33 PM
This answer has been confirmed as correct and helpful.
Malia is working with aluminum wire. While working with this type of wire, she must remember to A. always use pressure-type terminals. B. avoid copper connectors. C. avoid solder-type lugs. D. apply antioxidation paste.
Question|Asked by amelvin41
Not Answered
Updated 9/14/2022 5:01:22 PM
1 Answer/Comment
Malia is working with aluminum wire. While working with this type of wire, she must remember to: avoid copper connectors.
Added 9/14/2022 5:01:22 PM
This answer has been confirmed as correct and helpful.
Which type of circuit is becoming more common in residential electrical design and construction? A. Hazardous-area circuit B. Three-phase circuit C. 480-volt circuit D. Communication circuit
Question|Asked by amelvin41
Not Answered
Updated 4/17/2021 2:21:49 PM
1 Answer/Comment
Communication circuit is becoming more common in residential electrical design and construction.
Added 4/17/2021 2:21:49 PM
This answer has been confirmed as correct and helpful.
To protect all four receptacles on a branch circuit that surrounds a swimming pool, you would install which of the following configurations? A. GFCI feed-through receptacle at the end of the load's circuit B. GFCI-terminated receptacle at the beginning of the load's circuit C. GFCI feed-through receptacle at the beginning of the load's circuit and the other receptacles connected to the load side of that receptacle D. GFCI-terminated receptacle at each end of the load's circuit
Question|Asked by amelvin41
Not Answered
Updated 9/14/2022 4:58:24 PM
1 Answer/Comment
To protect all four receptacles on a branch circuit that surrounds a swimming pool, you would install the following configurations: GFCI feed-through receptacle at the beginning of the load's circuit and the other receptacles connected to the load side of that receptacle.
Added 9/14/2022 4:58:24 PM
This answer has been confirmed as correct and helpful.
When using two-wire cable to feed a 240-V appliance that does not require a neutral wire, you should A. mark both ends of the white wire green. B. use the cable as is. C. use only the black wire. D. mark both ends and any exposed area of the white wire black.
Question|Asked by amelvin41
Not Answered
Updated 9/14/2022 4:57:00 PM
1 Answer/Comment
When using two-wire cable to feed a 240-V appliance that does not require a neutral wire, you should mark both ends and any exposed area of the white wire black.
Added 9/14/2022 4:57:00 PM
This answer has been confirmed as correct and helpful.
39,049,174
questions answered
Popular Conversations
True or False: Chlorophyll is a pigment that absorbs light energy for ...
Weegy: The role of chlorophyll in photosynthesis is to absorb light for photosynthesis. User: True or False: ...
4/6/2024 8:58:35 AM| 6 Answers
True or False: The Hundred Years' War was fought between England and ...
Weegy: The Hundred Years' War was fought between France and England during the late Middle Ages. User: True or ...
4/6/2024 8:41:05 AM| 5 Answers
True or False: A SWOT analysis is used to assess a company's internal ...
Weegy: In a company's SWOT analysis, he following is an example of a threat: There are many competitors in the market. ...
4/6/2024 10:25:21 AM| 5 Answers
True or False: The term "double jeopardy" refers to being tried for ...
Weegy: Double jeopardy is the act of causing a person to be put on trial two times for the same crime. User: True ...
4/7/2024 11:32:54 AM| 4 Answers
True or False: Newton's first law states that an object in motion ...
Weegy: User: True or False: The Law of Conservation of Energy states that energy cannot be created or destroyed. ...
4/9/2024 5:58:15 AM| 4 Answers
Which of the following is not a type of muscle tissue? A) Skeletal B) ...
Weegy: Digestive is NOT a type of muscle tissue. User: What is the powerhouse of the cell where ATP is produced? ...
4/12/2024 8:10:09 AM| 4 Answers
Biological Energy Transformation
Weegy: Biological is used to describe processes and states that occur in the bodies and cells of living things. ...
4/3/2024 10:38:17 AM| 4 Answers
GET
Answers.
GET THE APP.
weegy*
*
Get answers from Weegy and a team of really smart live experts.
S
L
Points 252 [Total 252] Ratings 3 Comments 222 Invitations 0 Offline
S
L
Points 170 [Total 1532] Ratings 1 Comments 160 Invitations 0 Offline
S
L
Points 142 [Total 1681] Ratings 0 Comments 142 Invitations 0 Offline
S
L
L
Points 94 [Total 7074] Ratings 1 Comments 84 Invitations 0 Offline
S
Points 20 [Total 20] Ratings 0 Comments 0 Invitations 2 Offline
S
Points 10 [Total 10] Ratings 0 Comments 0 Invitations 1 Offline
S
L
R
Points 10 [Total 329] Ratings 0 Comments 10 Invitations 0 Offline
S
L
1
1
1
1
Points 10 [Total 2265] Ratings 1 Comments 0 Invitations 0 Offline
S
L
P
Points 7 [Total 3319] Ratings 0 Comments 7 Invitations 0 Offline
S
Points 5 [Total 5] Ratings 0 Comments 5 Invitations 0 Offline
* Excludes moderators and previous
winners (Include)
Home | Contact | Blog | About | Terms | Privacy | © Purple Inc.